October 2013 – Ed.1.0
EQUITEL E400 Family – Control and communications protocol
Page 9
Communications monitoring with SIP:
Message Address Description
DEMCALLSIP E400 CC User SIP call
ACK_DEMCALLSIP CC E400 ACK corresponding to DEMCALLSIP
OUTCALLRINGING E400 CC Ringing, call with origin E400 (outgoing)
ACK_ OUTCALLRINGING CC E400 ACK corresponding to OUTCALLRINGING
INCALLRINGING E400 CC Ringing, call with destination E400 (incoming)
ACK_ INCALLRINGING CC E400 ACK corresponding to INCALLRINGING
CONNECTEDCALL E400 CC Beginning of SIP conversation – active audio
ACK_CONNECTEDCALL CC E400 ACK corresponding to CONNECTEDCALL
DISCONNECTEDCALL E400 CC End of SIP call – audio deactivated
ACK_ DISCONNECTEDCALL CC E400 ACK corresponding to DISCONNECTEDCALL
In the column “Message” it is shown only the COMMAND part of each delivery or answer message. As a
reminder, they may need one or several parameters separated by “/” and they must end always with the
symbol “&”.
In the column “Address” it is indicated “E400 CC” for the messages going from the E400 family modules
towards the controller. With “CC E400” the ones going the other way.
In the following points we will describe the different messages sorted out by functionality.
NOTE: In order to simplify the explanations, from now on when mentioning “E400” we will refer to both E401
and E451 since regarding the protocol software, the differences are not important
(5)
.
(5) The sections corresponding to the intrinsic functionalities of one or another equipment will be clearly marked
Comentarios a estos manuales